Based on Direct Digital Synthesized (DDS) technology and unique FPGA design, SFG-2000/2100 Series  
 Function Generators are built with exceptionally high performance far exceeding that of any conventional  
 function generators, at a very competitive price. Stable output frequency, low distortion, and fine  
 frequency resolution are the most remarkable characteristics of this product series.  | 
 
 
 MAIN  | 
 
 
 Frequency Range 
 (For Sine, Square)  | 
 1Hz~20MHz  | 
 
 
 Frequency Range 
 (For Triangle)  | 
 1Hz~1MHz  | 
 
 
 Frequency Resolution  | 
 1Hz   | 
 
 
 Frequency Stability  | 
 ∮ 20 ppm  | 
 
 
 Frequency Accuracy  | 
 ∮ 20 ppm   | 
 
 
 Frequency Aging   | 
 ∮ 5 ppm / year  | 
 
 
 Output Function  | 
 Sine, Square, Triangle  | 
 
 
 Amplitude Range  | 
 2mV~10Vpp(into 50?load)  | 
 
 
 Impedance  | 
 50?∮10?  | 
 
 
 Attenuator  | 
 -20dB∮1dB⊙2   | 
 
 
 DC Offset  | 
 ≌-5V°≈+5V(into 50?load)   | 
 
 
 Duty Control Range   | 
 20% to 80%, 2Hz~1MHz (Square wave only)   | 
 
 
 Range Resolution   | 
 1%   | 
 
 
 Display  | 
 9 digits LED display   | 
 
 
 SINE WAVE  | 
 
 
 Harmonics Distortion  | 
 -55dBc,0.1Hz°200kHz; -40dBc,0.2MHz°4MHz; -30dBc,4MHz°10MHz 
 (Specification applied to both TTL/CMOS OFF and from MAX. to 1/10 level)  | 
 
 
 Flatness (Relative to 1kHz)  | 
 ≌∮ 0.3dB,0.1Hz°1MHz; ≌∮ 0.5dB,1MHz°4MHz; ≌∮ 2dB, 4MHz°10MHz  | 
 
 
 TRIANGLE WAVE  | 
 
 
 Linearity  | 
 ≠98?,0.1Hz°100kHz;≠95?,100kHz°1MHz   | 
 
 
 SQUARE WAVE  | 
 
 
 Symmetry  | 
 ∮ 1% of period +4ns to 0.1Hz°100kHz   | 
 
 
 Rise or Fall Time  | 
 ∝25ns at maximum output.(into 50?load)  | 
 
 
 CMOS OUTPUT  | 
 
 
 Level  | 
 4Vpp∮1Vpp°15Vpp∮1Vpp adjustable; Rise or Fall Time ∝120ns  | 
 
 
 TTL OUTPUT  | 
 
 
 Level  | 
 ≠3Vpp ; Fan Out; 20 TTL load ; Rise or Fall Time ∝25ns  | 
 
 
 SWEEP OPERATION   | 
 
 
 Rate   | 
 100:1 ratio max. and adjustable  
 ( In order to get maximum sweep span, the sweep time needs to be tuned on when adjust sweep span. )  | 
 
 
 Time  | 
 1Sec°30Sec adjustable  
 ( When the sweep time is too long, the stop frequency will reach and stay at the maximum frequency of instrument until the end of the sweep cycle. )  | 
 
 
 Mode  | 
 Lin./Log. switch selector  | 
 
 
 AMPLITUDE MODULATION   | 
 
 
 Depth & Modulation Frequency  | 
 0°100? ; 400Hz(INT), DC°1MHz(EXT)  | 
 
 
 Carrier BW  | 
 100Hz°5MHz(-3dB)  | 
 
 
 EXT Modulation Sensitivity  | 
 ∝ 10Vpp for 100?modulation   | 
 
 
 FREQUENCY MODULATION   | 
 
 
 Deviation & Modulation Frequency  | 
 0°∮50kHz,center at 1MHz, 400Hz fixed(INT), 1kHz fixed(EXT)   | 
 
 
 EXT Modulation Sensitivity  | 
 ∝ 10Vpp for 10% modulation (center at 1MHz)   | 
 
 
 FREQUENCY COUNTER   | 
 
 
 Range   | 
 5Hz°150MHz   | 
 
 
 Accuracy   | 
 Time base accuracy∮1count   | 
 
 
 Time base   | 
 ∮20ppm(23?∮5?)after 30 minutes warm up  | 
 
 
 Resolution   | 
 The maximum resolution is 100nHz for 1Hz and 0.1Hz for 100MHz   | 
 
 
 Input Impedance  | 
 1M?/150pf   | 
 
 
 Sensitivity  | 
 ∝ 35mVrms (5Hz~100MHz) 
 ∝ 45mVrms (100MHz~150MHz)  | 
 
 
 STORE/RECALL FUNCTION  | 
 
 
 |   | 
 10 groups of Setting memories   | 
 
 
 POWER SOURCE  | 
   | 
 
 
 |   | 
 AC115V∮10%, AC 230V+10%/-15%, 50/60Hz   | 
 
 
 ACCESSORIES   | 
 
 
 |   | 
 Instruction manual⊙1 
 Power Cord x 1 
 GTL-101⊙ 2  | 
 
 
 DIMENSION & WEIGHT  | 
 266(W)⊙107(H)⊙293(D) mm 
 Approx. 3.2kg  |